INTERPRETACION DE CAMPIMETRIA PDF

Dra. Lourdes Peñaló; Oftalmóloga; Instituto de Especialidades Médicas“ Dr. Gregorio Hernández ”, Moca; Oftalmogroup (Centro Diagnóstico. Defecto homónimo que respeta la linea media vertical. Anteriores: incongruentes .Controversia. Causas: tumores; aneurismas; acv y tx. Ventajas: Simple y rápido. Fácil de interpretar. Interpretación de Exámenes: Observando la gráfica, la CAMPIMETRÍA COMPUTARIZADA. Uploaded by.

Author: Yozshukinos Nedal
Country: Suriname
Language: English (Spanish)
Genre: Education
Published (Last): 17 April 2014
Pages: 347
PDF File Size: 15.81 Mb
ePub File Size: 14.27 Mb
ISBN: 456-8-27364-523-9
Downloads: 26166
Price: Free* [*Free Regsitration Required]
Uploader: Arashir

Optic nerve head parameters as measured by confocal scanning laser Heidelberg Retina Tomograph II in normal, ocular hypertensive and glaucomatous subjects. Hospital Universitario Miguel Servet. Hospital de la Esperanza. Se incluyeron ojos de sujetos normales, ojos de hipertensos oculares y ojos de glaucomatosos.

To compare the optic nerve parameters measured by confocal scanning laser in normal, ocular hypertensive and glaucomatous eyes; and in groups of ocular hypertensive eyes, classification of these according to the optic nerve appearance and to short-wavelength automated perimetry SWAP results.

Subjects were classified based on intraocular pressure and standard automated perimetry AP performance. Hypertensive subjects were classified into ocular hypertensive and preperimetric glaucoma, and into ocular hypertensive with normal SWAP and hypertensive with pathological SWAP findings.

Every patient underwent evaluation of the optic nerve, AP, SWAP and confocal scanning laser ophthalmoscopy HRT IIresulting in the acquisition of topographic parameters of the optic nerve, which were then compared between the different groups.

  IMAGINE THIS BY SADE ADENIRAN PDF

Ocular hypertensive eyes showed an overlap when compared with normal and glaucoma groups. No differences were found between normal subjects and those with ocular hypertension in mean retinal nerve fiber layer thickness 0. Nevertheless, when those with ocular hypertension were segregated based on clinical evaluation of optic nerve or SWAP performance, the ability to define the presence of structural glaucoma damage improved significantly.

HRT enables moderate discrimination between normal, ocular hypertensive and glaucoma subjects. The use of diagnostic tests to detect early glaucomatous damage such as short-wavelength automated perimetry in ocular hypertensive eyes improves the ability of HRT to discriminate glaucoma.

Glaucoma, diagnosis, HRT, optic nerve head. Se han incluido en el presente estudio un total de ojos de sujetos. Se obtuvo consentimiento informado.

Foro casiMedicos 2006-2010 (Solo Lectura) Nuevo Foro en http://www.casimedicos.com/foro/

Los sujetos incluidos fueron clasificados en tres grupos de estudio: Pattern of glaucomatous neuroretinal rim loss. Optic disc, cup and neuroretinal rim size, configuration and correlations in normal eyes.

Invest Ophthalmol Vis Sci ; Short-wavelength automated perimetry and retinal nerve fiber layer evaluation in suspects cases of glaucoma.

Arch Ophthalmol ; Clinically detectable nerve interpretacioh layer atrophy predeces the onset of glaucomatous field loss. Visual field interpretation with empiric probability maps.

Predictive value of short-wavelength automated perimetry: Neuroretinal rim area in suspected glaucoma and early chronic open-angle glaucoma. Correlation with parameters of visual function. Neuroretinal rim area in early glaucoma.

  FCS 9013 PDF

Am J Ophthalmol ; Abecia E, Honrubia FM. Retinal nerve fiber layer defects and automated perimetry evaluation in ocular hypertensives. Int Ophthalmol ; Tuulonen A, Airaksinen PJ. Initial glaucomatous optic disk and retinal nerve fiber layer abnormalities and their progression. Rate and pattern of neuroretinal rim area decrease in ocular hypertension and glaucoma.

Optic disk ce in ocular hypertensive eyes. Ability interpretacjon the heidelberg retina tomograph to detect early glaucomatous visual field loss.

J Glaucoma ; 4: The effect of optic disc size on camplmetria precision with the Heidelberg retina tomograph. Detection of early glaucomatous structural damage with confocal scanning laser tomography.

Campimetria ocular — Поиск по картинкам — [RED]

J Glaucoma ; 7: Detection of structural damage from glaucoma with confocal jnterpretacion image analysis. Detection of optic disc change with the Heidelberg retina tomograph before confirmed visual field change in ocular hypertensives converting to early glaucoma.

Br J Ophthalmol ; Identification of early glaucoma cases with the scanning laser ophthalmoscope. Brigatti L, Caprioli J. Correlation of visual interpregacion with scanning confocal laser optic disc measurements in glaucoma. Correlation of peripapillary retinal height and visual field in glaucoma and normal subjects.